Fire all oil Burners are rugged, maintenance free, sealed in burners for burning light or heavy oil on a wide variety of applications. Oil viscosity at the burners should not exceed 100 SSU. Minimum atomizing pressure at the burner is 14 osi for light oil, 22 osi for heavy oil.
Burner Size | Air Pressure 1055mm (40” ) WG |
---|---|
54-6 | 55 LPH |
54-7 | 88 LPH |
54-8A | 151 LPH |
54- 8B | 252 LPH |
The Parameters are approximate as per working conditions and are subject to change
Burner Size | AIR PRESSURE AT 40” WG |
---|---|
62-3 | 15 LPH |
62-4 | 20 LPH |
62-5 | 36 LPH |
The Parameters are approximate as per working conditions and are subject to change
Fire All Dual Fuel Burners are nozzle mix, sealed in burners for gas, light oil or heavy oil. Capable of efficient operation throughout a wide temperature range, these burners are equally at home on low temperature ovens and high temperature forge and melting furnaces.
Ruggedly built for sustained, maintenance-free operation, 64 burners also provide for quick change of fuels without disturbing process operations.
Oil viscosity at the burners should not exceed 100 SSU. Minimum atomizing pressure at the burner is 14 osi for light oil, 22 osi for heavy oil.
Burner Size | Air Pressure 1055mm (40” ) WG |
---|---|
54-6 | 55 LPH |
54-7 | 88 LPH |
54-8A | 151 LPH |
54- 8B | 252 LPH |
The Parameters are approximate as per working conditions and are subject to change
Burner Size | AIR PRESSURE 890 MM (36”) WG |
---|---|
1 | 6.8 LPH |
2 | 9.5 LPH |
3 | 17.5 LPH |
3A | 27.0 LPH |
4 | 36.0 LPH |
4A | 58.8 LPH |
5 | 72.0 LPH |
5A | 110.2 LPH |
The Parameters are approximate as per working conditions and are subject to change
Series 66-54 Dual Fuel Burner offered in sizes 3, 4, 5, 6, 7A extended downward the range of sizes of heavy oil cold air sealed in burners utilizing the efficient “ tip emulsion” type atomizer. These burners make it possible to use the current heavy residual oils (heated to a viscosity of 100 SSU) in the range of 25 gph down to less than 2 gph ( 96 to 8.5 ltrs/hr.) with good flame characteristics with in a limited range of lean (excess air) to rich (excess fuel) operation. Low Pressure Air (36osi) i.e 63” is used as the atomizing medium for proper atomization of heavy oil (Residual Oil/Furnace Oil). Fuel can be used.
Furnace oil/RFO, LDO/C9, Coke oven Gas, Natural Gas (PNG), LPG
Burner Size | Air Pressure 703 MM (28” ) WG |
---|---|
66-54-2 | 6 LPH |
66-54-3 | 10.5 LPH |
66-54-4 | 16.5 LPH |
66-54-5 | 23.5 LPH |
66-54- 6 | 41 LPH |
66-54-7A | 74 LPH |
The Parameters are approximate as per working conditions and are subject to change